I would like to run multiple copies of my application and force the first to open on one monitor and the second instance on a second monitor
R – How to force a .net application to display on a particular monitor in a dual monitor setup
multiple-monitorsnet
Related Solutions
Here is a very good article regarding the Mutex solution. The approach described by the article is advantageous for two reasons.
First, it does not require a dependency on the Microsoft.VisualBasic assembly. If my project already had a dependency on that assembly, I would probably advocate using the approach shown in another answer. But as it is, I do not use the Microsoft.VisualBasic assembly, and I'd rather not add an unnecessary dependency to my project.
Second, the article shows how to bring the existing instance of the application to the foreground when the user tries to start another instance. That's a very nice touch that the other Mutex solutions described here do not address.
UPDATE
As of 8/1/2014, the article I linked to above is still active, but the blog hasn't been updated in a while. That makes me worry that eventually it might disappear, and with it, the advocated solution. I'm reproducing the content of the article here for posterity. The words belong solely to the blog owner at Sanity Free Coding.
Today I wanted to refactor some code that prohibited my application from running multiple instances of itself.
Previously I had use System.Diagnostics.Process to search for an instance of my myapp.exe in the process list. While this works, it brings on a lot of overhead, and I wanted something cleaner.
Knowing that I could use a mutex for this (but never having done it before) I set out to cut down my code and simplify my life.
In the class of my application main I created a static named Mutex:
static class Program
{
static Mutex mutex = new Mutex(true, "{8F6F0AC4-B9A1-45fd-A8CF-72F04E6BDE8F}");
[STAThread]
...
}
Having a named mutex allows us to stack synchronization across multiple threads and processes which is just the magic I'm looking for.
Mutex.WaitOne has an overload that specifies an amount of time for us to wait. Since we're not actually wanting to synchronizing our code (more just check if it is currently in use) we use the overload with two parameters: Mutex.WaitOne(Timespan timeout, bool exitContext). Wait one returns true if it is able to enter, and false if it wasn't. In this case, we don't want to wait at all; If our mutex is being used, skip it, and move on, so we pass in TimeSpan.Zero (wait 0 milliseconds), and set the exitContext to true so we can exit the synchronization context before we try to aquire a lock on it. Using this, we wrap our Application.Run code inside something like this:
static class Program
{
static Mutex mutex = new Mutex(true, "{8F6F0AC4-B9A1-45fd-A8CF-72F04E6BDE8F}");
[STAThread]
static void Main() {
if(mutex.WaitOne(TimeSpan.Zero, true)) {
Application.EnableVisualStyles();
Application.SetCompatibleTextRenderingDefault(false);
Application.Run(new Form1());
mutex.ReleaseMutex();
} else {
MessageBox.Show("only one instance at a time");
}
}
}
So, if our app is running, WaitOne will return false, and we'll get a message box.
Instead of showing a message box, I opted to utilize a little Win32 to notify my running instance that someone forgot that it was already running (by bringing itself to the top of all the other windows). To achieve this I used PostMessage to broadcast a custom message to every window (the custom message was registered with RegisterWindowMessage by my running application, which means only my application knows what it is) then my second instance exits. The running application instance would receive that notification and process it. In order to do that, I overrode WndProc in my main form and listened for my custom notification. When I received that notification I set the form's TopMost property to true to bring it up on top.
Here is what I ended up with:
- Program.cs
static class Program
{
static Mutex mutex = new Mutex(true, "{8F6F0AC4-B9A1-45fd-A8CF-72F04E6BDE8F}");
[STAThread]
static void Main() {
if(mutex.WaitOne(TimeSpan.Zero, true)) {
Application.EnableVisualStyles();
Application.SetCompatibleTextRenderingDefault(false);
Application.Run(new Form1());
mutex.ReleaseMutex();
} else {
// send our Win32 message to make the currently running instance
// jump on top of all the other windows
NativeMethods.PostMessage(
(IntPtr)NativeMethods.HWND_BROADCAST,
NativeMethods.WM_SHOWME,
IntPtr.Zero,
IntPtr.Zero);
}
}
}
- NativeMethods.cs
// this class just wraps some Win32 stuff that we're going to use
internal class NativeMethods
{
public const int HWND_BROADCAST = 0xffff;
public static readonly int WM_SHOWME = RegisterWindowMessage("WM_SHOWME");
[DllImport("user32")]
public static extern bool PostMessage(IntPtr hwnd, int msg, IntPtr wparam, IntPtr lparam);
[DllImport("user32")]
public static extern int RegisterWindowMessage(string message);
}
- Form1.cs (front side partial)
public partial class Form1 : Form
{
public Form1()
{
InitializeComponent();
}
protected override void WndProc(ref Message m)
{
if(m.Msg == NativeMethods.WM_SHOWME) {
ShowMe();
}
base.WndProc(ref m);
}
private void ShowMe()
{
if(WindowState == FormWindowState.Minimized) {
WindowState = FormWindowState.Normal;
}
// get our current "TopMost" value (ours will always be false though)
bool top = TopMost;
// make our form jump to the top of everything
TopMost = true;
// set it back to whatever it was
TopMost = top;
}
}
Apart from the apparent difference of
- having to declare the value at the time of a definition for a
const
VSreadonly
values can be computed dynamically but need to be assigned before the constructor exits.. after that it is frozen. const
's are implicitlystatic
. You use aClassName.ConstantName
notation to access them.
There is a subtle difference. Consider a class defined in AssemblyA
.
public class Const_V_Readonly
{
public const int I_CONST_VALUE = 2;
public readonly int I_RO_VALUE;
public Const_V_Readonly()
{
I_RO_VALUE = 3;
}
}
AssemblyB
references AssemblyA
and uses these values in code. When this is compiled:
- in the case of the
const
value, it is like a find-replace. The value 2 is 'baked into' theAssemblyB
's IL. This means that if tomorrow I updateI_CONST_VALUE
to 20,AssemblyB
would still have 2 till I recompile it. - in the case of the
readonly
value, it is like aref
to a memory location. The value is not baked intoAssemblyB
's IL. This means that if the memory location is updated,AssemblyB
gets the new value without recompilation. So ifI_RO_VALUE
is updated to 30, you only need to buildAssemblyA
and all clients do not need to be recompiled.
So if you are confident that the value of the constant won't change, use a const
.
public const int CM_IN_A_METER = 100;
But if you have a constant that may change (e.g. w.r.t. precision).. or when in doubt, use a readonly
.
public readonly float PI = 3.14;
Update: Aku needs to get a mention because he pointed this out first. Also I need to plug where I learned this: Effective C# - Bill Wagner
Related Topic
- C# – How to enumerate an enum
- C# – Catch multiple exceptions at once
- C# – Proper use of the IDisposable interface
- .net – Difference between decimal, float and double in .NET
- C# – How to update the GUI from another thread
- C# – How to get the application’s path in a .NET console application
- C# – How to remedy “The breakpoint will not currently be hit. No symbols have been loaded for this document.” warning
- C# – How to force the .NET application to run as administrator
Best Answer
will give you the size and position information for both monitors.
should pop a form up in your second monitor.